zudo-led-lamp
GitHub repository

Type to search...

to open search from anywhere

CC0603KRX7R9BB104

100 nF 50 V MLCC — Yageo — C14663 — board-p C2, C35; board-l C20, C24, C13, C15, C18, C21, C22 — rec-c14663

Everything below is projected from this project's stored component evidence. Values keep the exact wording, conditions, units and verdicts they were recorded with — nothing here is re-typed, corrected, or combined into an overall judgement about the part.

This record in the catalog: CC0603KRX7R9BB104

Identity

  • Record ID: rec-c14663

  • Record kind: standalone

  • Manufacturer part number: CC0603KRX7R9BB104

  • Manufacturer: Yageo

  • Function: 100 nF 50 V MLCC

  • LCSC ID: C14663

  • Package: C0603

  • Inventory line: line-c14663

  • Owner skill: component-project-passives

  • Fit: Fitted

  • Identity state: UNRESOLVED

  • Source state: SOURCE UNAVAILABLE

  • Coverage: 3 open of 5 published

Component references

Footprint preview

Footprint preview for C0603
Shared footprint package: C0603. Open SVG

Footprint preview for C0603

Package model

Shared footprint package: C0603

Interactive inspection requires JavaScript and WebGL. The package identity remains available in this page.

This geometry represents a shared footprint package and may not exactly match the manufacturer part.

Interactive 3D view of shared footprint package C0603

Placements

Every position this exact line occupies in the as-built design. One line may be placed many times and across more than one board.

BoardReference designator
board-pC2
board-pC35
board-lC20
board-lC24
board-lC13
board-lC15
board-lC18
board-lC21
board-lC22

Coverage

Coverage is stated one domain at a time and is never rolled up. A domain marked open is a question that has not been answered; it is not a finding that the part is unsuitable. A record with no open domains has not thereby been declared safe.

identity-and-rated-capacitance

  • Coverage ID: cov-c14663-identity

  • Status: COVERED

Reason: fact-c14663-manufacturer; fact-c14663-capacitance; fact-c14663-voltage

Facts in this domain:

dielectric-temperature-and-termination

  • Coverage ID: cov-c14663-temp

  • Status: COVERED

Reason: fact-c14663-dielectric; fact-c14663-termination

Facts in this domain:

effective-capacitance-under-installed-bias

  • Coverage ID: cov-c14663-bias

  • Status: OPEN

Reason: fact-c14663-simulation-caveat: simulation is not specification

Facts in this domain:

Blocked by: these facts must be resolved before the domain can close. Each is listed in full under Facts.

aging-at-installed-condition

  • Coverage ID: cov-c14663-aging

  • Status: OPEN

Reason: fact-c14663-simulation-caveat: exact aging condition is not retained

Facts in this domain:

Blocked by: these facts must be resolved before the domain can close. Each is listed in full under Facts.

ripple-current-under-installed-layout

  • Coverage ID: cov-c14663-ripple

  • Status: OPEN

Reason: fact-c14663-simulation-caveat: simulation is not a maximum capability

Facts in this domain:

Blocked by: these facts must be resolved before the domain can close. Each is listed in full under Facts.

Facts

Each fact keeps its value, its unit, the conditions it holds under, where it came from and how far it has been confirmed as separate fields, because they are separate claims. A value without its conditions is not the same fact, and a verdict is about the evidence for the value, not about the part.

ABSOLUTE_MAXIMUM

A never-exceed limit. Reaching it may damage the part; it is not an operating target and there is no margin implied by it.

FactValueUnitConditionsVerdictProvenanceEvidence
fact-c14663-voltage50Vdcrated DC voltagePASS - primary-source confirmedPRIMARY-SPECsrc-c14663-yageo: page 1, Specifications table, row Voltage DC

GUARANTEED_ELECTRICAL

A parameter the manufacturer guarantees over the stated conditions, usually with minimum, typical and maximum values.

FactValueUnitConditionsVerdictProvenanceEvidence
fact-c14663-capacitance0.1uFnominalPASS - primary-source confirmedPRIMARY-SPECsrc-c14663-yageo: page 1, Specifications table, row Capacitance
fact-c14663-tolerance10%tolerancePASS - primary-source confirmedPRIMARY-SPECsrc-c14663-yageo: page 1, Specifications table, row Tolerance
fact-c14663-dielectricX7R, -55 to +125 CNONEtemperature coefficient/rangePASS - primary-source confirmedPRIMARY-SPECsrc-c14663-yageo: page 1, Specifications table, rows Temperature Range and Temp. Coefficient

TYPICAL_CURVE

A representative figure read from a characteristic curve. Typical values are not guaranteed and vary part to part.

FactValueUnitConditionsVerdictProvenanceEvidence
fact-c14663-simulation-caveatSimulation response is not a specification and is not a specified or implied maximum capabilityNONEDC bias/ripple/temperature simulation pagesNEEDS BENCHPRIMARY-SPECSection evidence, src-c14663-yageo: page 4, simulation disclaimer paragraphs

PROJECT_STATE

A value this project recorded about how the part is used here — a chosen operating point, a net assignment, or a derived figure. Not a manufacturer specification.

FactValueUnitConditionsVerdictProvenanceEvidence
fact-c14663-manufacturerYageoNONEexact orderable CC0603KRX7R9BB104PASS - primary-source confirmedPRIMARY-SPECsrc-c14663-yageo: page 1, title block
fact-c14663-termination0603/1608, tin terminationNONEpackage dimensionsPASS - primary-source confirmedPRIMARY-SPECsrc-c14663-yageo: page 1, General Information and Dimensions tables
fact-c14663-c35-topologyC35 is between Q1_G and VBUS_IN, not groundNONEcurrent generated Board P netlistNOT APPLICABLEREFERENCE-DESIGNsrc-c14663-generator: NETS mapping, rows VBUS_IN and Q1_G

Pin maps

The mapping between schematic pins and PCB pads, or physical terminals for an external part, as recorded. A record may carry more than one map when the same part is documented in more than one context.

pinmap-c14663

  • Symbol: CC0603KRX7R9BB104

  • Footprint: C0603

  • Pins: 2

Pin assignments
Symbol pinNameFootprint padFunction
1terminal-11passive terminal
2terminal-22passive terminal

Interactions

Behaviour that is not a property of this part alone. Each interaction names the records it spans, the conditions it holds under, and how far it has been confirmed. An interaction that spans several parts appears on every one of their pages, under the same identifier, because it is equally a fact about each.

int-c14663-c35

  • Records involved: rec-c14663 (this record)

  • Conditions: C35 current topology is gate-to-VBUS_IN; C2 and Board L decouplers use same orderable line

  • Verdict: NEEDS BENCH

Facts this rests on:

Cross-component rules

Rules that span several parts at once and are published in full on the integration page. Each rule's verdict below is that rule's own — it is a statement about the cross-component question, not about this part — and the exact wording of what the rule refuses to conclude is published with the rule itself.

  • rule-rail-envelope — rail-envelope — rule verdict: UNSOURCED — Whether every part on the input rail stays inside its own recorded limits across a legal power contract, a mis-contract, and a transient clamp event.

  • rule-usb-pd-nvm-load-switch — usb-pd-nvm-load-switch — rule verdict: UNSOURCED — How the power-delivery controller's stored configuration and its enable output drive the load switch, through every state from detached to fault.

  • rule-c470643-brightness-adc — potentiometer-brightness-adc — rule verdict: NEEDS BENCH

All cross-component rules

Sources

Every document cited above, with its identification, when it was retrieved, and what kind of authority it carries. Sources that could not be retrieved are listed too, with their unavailability stated, so a gap in the evidence is visible rather than absent.

Yageo CC0603KRX7R9BB104 specification sheet

  • Source ID: src-c14663-yageo

  • Document number: CC0603KRX7R9BB104

  • Revision: generated 2026-08-01

  • Document date: 2026-08-01

  • Retrieved: 2026-08-02

  • Authority: MANUFACTURER_PRIMARY

  • Locator: Specifications table, rows Capacitance through Endurance

  • Printed page: 1

  • Availability: AVAILABLE

  • Document URL: https://yageogroup.com/download/specsheet/CC0603KRX7R9BB104

Board P generated schematic specification

Legend

What the recorded terms on this page mean, in ordinary words. The exact terms above are the ones that count; these descriptions explain them and never replace them.

Verdict

Recorded termWhat it means
NEEDS BENCHCannot be settled from documents. It needs measurement on real hardware before it can be relied on.
NOT APPLICABLEThe parameter does not apply to this part as it is used here.
PASS - primary-source confirmedConfirmed against the manufacturer's own document for this exact part.

Provenance

Recorded termWhat it means
PRIMARY-SPECTaken from the manufacturer's own specification document.
REFERENCE-DESIGNTaken from a vendor reference design or application note rather than the device specification.

Fact class

Recorded termWhat it means
ABSOLUTE_MAXIMUMA never-exceed limit. Reaching it may damage the part; it is not an operating target and there is no margin implied by it.
GUARANTEED_ELECTRICALA parameter the manufacturer guarantees over the stated conditions, usually with minimum, typical and maximum values.
PROJECT_STATEA value this project recorded about how the part is used here — a chosen operating point, a net assignment, or a derived figure. Not a manufacturer specification.
TYPICAL_CURVEA representative figure read from a characteristic curve. Typical values are not guaranteed and vary part to part.

Coverage status

Recorded termWhat it means
COVEREDEvery question this domain asks is answered by the facts listed against it.
OPENUnresolved. Open means the question has not been answered, not that the part is unsafe — the reason states what is missing.

Source availability

Recorded termWhat it means
AVAILABLEThe document was retrieved and is on record.

Source authority

Recorded termWhat it means
MANUFACTURER_PRIMARYThe manufacturer's own document for this exact part.
PROJECT_GENERATORA document this project generated, such as a schematic or netlist export.

Identity state

Recorded termWhat it means
UNRESOLVEDThe exact orderable part is not yet confirmed. Substituting a same-name part from another vendor is not permitted on that basis.

Source state

Recorded termWhat it means
SOURCE UNAVAILABLENo document backing this line could be retrieved.

Unit

Recorded termWhat it means
NONEThe value is not a physical quantity, so it carries no unit. Recorded as `NONE`.

Raw agent resource

This page is generated from a stored evidence bundle and does not restate it. The bundle is the source of truth: where the two ever disagree, the bundle is right and this page is stale.

Open the owning bundle component-project-passives