zudo-led-lamp
GitHub repository

Type to search...

to open search from anywhere

0603WAF3302T5E

33 kOhm resistor — UNI-ROYAL — C4216 — board-l R21 — rec-c4216

Everything below is projected from this project's stored component evidence. Values keep the exact wording, conditions, units and verdicts they were recorded with — nothing here is re-typed, corrected, or combined into an overall judgement about the part.

This record in the catalog: 0603WAF3302T5E

Identity

  • Record ID: rec-c4216

  • Record kind: standalone

  • Manufacturer part number: 0603WAF3302T5E

  • Manufacturer: UNI-ROYAL

  • Function: 33 kOhm resistor

  • LCSC ID: C4216

  • Package: R0603

  • Inventory line: line-c4216

  • Owner skill: component-project-passives

  • Fit: Fitted

  • Identity state: UNRESOLVED

  • Source state: SOURCE UNAVAILABLE

  • Coverage: 1 open of 2 published

Component references

Footprint preview

Footprint preview for R0603
Shared footprint package: R0603. Open SVG

Footprint preview for R0603

Package model

Shared footprint package: R0603

Interactive inspection requires JavaScript and WebGL. The package identity remains available in this page.

This geometry represents a shared footprint package and may not exactly match the manufacturer part.

Interactive 3D view of shared footprint package R0603

Placements

Every position this exact line occupies in the as-built design. One line may be placed many times and across more than one board.

BoardReference designator
board-lR21

Coverage

Coverage is stated one domain at a time and is never rolled up. A domain marked open is a question that has not been answered; it is not a finding that the part is unsuitable. A record with no open domains has not thereby been declared safe.

identity-value-tolerance-and-thermal-rating

  • Coverage ID: cov-c4216-rating

  • Status: COVERED

Reason: fact-c4216-manufacturer; fact-c4216-resistance; fact-c4216-tolerance; fact-c4216-power; fact-c4216-tcr; fact-c4216-voltage

Facts in this domain:

pulse-energy-at-installed-waveform

  • Coverage ID: cov-c4216-pulse

  • Status: OPEN

Reason: fact-c4216-pulse-caveat

Facts in this domain:

Blocked by: these facts must be resolved before the domain can close. Each is listed in full under Facts.

Facts

Each fact keeps its value, its unit, the conditions it holds under, where it came from and how far it has been confirmed as separate fields, because they are separate claims. A value without its conditions is not the same fact, and a verdict is about the evidence for the value, not about the part.

ABSOLUTE_MAXIMUM

A never-exceed limit. Reaching it may damage the part; it is not an operating target and there is no margin implied by it.

FactValueUnitConditionsVerdictProvenanceEvidence
fact-c4216-voltage75V0603 maximum continuous working voltage; overload max 150 VPASS - primary-source confirmedPRIMARY-SPECsrc-c4216-uniroyal: page 5, Ratings table, 0603 row

The range the manufacturer intends the part to be used in. Always narrower than the absolute maximum.

FactValueUnitConditionsVerdictProvenanceEvidence
fact-c4216-power0.1W0603 WA normal-size rating, ambient at or below 70 CPASS - primary-source confirmedPRIMARY-SPECsrc-c4216-uniroyal: pages 2 and 4, Part No. System and Resistance Range table
fact-c4216-rcwv-squared3300V2P times R under source RCWV equation; use sqrt result and 75 V capPASS - primary-source confirmedCALCULATEDSection evidence, src-c4216-uniroyal: page 5, Derating Curve and RCWV equation

GUARANTEED_ELECTRICAL

A parameter the manufacturer guarantees over the stated conditions, usually with minimum, typical and maximum values.

FactValueUnitConditionsVerdictProvenanceEvidence
fact-c4216-resistance33000Ohm3302 code: 330 times 10 to power 2PASS - primary-source confirmedPRIMARY-SPECSection evidence, src-c4216-uniroyal: page 2, Part No. System, resistance-value code
fact-c4216-tolerance1%F tolerance codePASS - primary-source confirmedPRIMARY-SPECSection evidence, src-c4216-uniroyal: page 2, Part No. System, tolerance code
fact-c4216-tcr100ppm/C0603 resistance above 10 OhmPASS - primary-source confirmedPRIMARY-SPECsrc-c4216-uniroyal: page 6, Temperature Coefficient table, 0603 row

TRANSIENT

Behaviour during a short event — startup, a switching edge, a fault or a surge.

FactValueUnitConditionsVerdictProvenanceEvidence
fact-c4216-pulse-caveatNo exact installed-waveform pulse-energy rating is retainedNONEonly 5-second short-time-overload test is specifiedNEEDS BENCHPRIMARY-SPECsrc-c4216-uniroyal: page 6, Short-time overload row

PROJECT_STATE

A value this project recorded about how the part is used here — a chosen operating point, a net assignment, or a derived figure. Not a manufacturer specification.

FactValueUnitConditionsVerdictProvenanceEvidence
fact-c4216-manufacturerUNI-ROYALNONEexact orderable 0603WAF3302T5EPASS - primary-source confirmedPRIMARY-SPECSection evidence, src-c4216-uniroyal: page 2, Scope paragraph 1.1 and Part No. System
fact-c4216-ctrl-topologyR21 is a 33 kOhm CTRL-to-GND leg with R20 and C21 at CTRLNONEcurrent generated Board L netlist; drive-level calculation needs active-device limitsNOT APPLICABLEREFERENCE-DESIGNsrc-c4216-generator: NETS mapping, row CTRL

Calculation dependencies

These values were derived from other recorded facts rather than read from a document. The expression and every input are published so the number can be recomputed instead of trusted. A derived value is never stronger than the weakest fact it depends on.

FactExpressionDepends on
fact-c4216-rcwv-squaredfact_c4216_power * fact_c4216_resistancefact-c4216-power, fact-c4216-resistance

Pin maps

The mapping between schematic pins and PCB pads, or physical terminals for an external part, as recorded. A record may carry more than one map when the same part is documented in more than one context.

pinmap-c4216

  • Symbol: 0603WAF3302T5E

  • Footprint: R0603

  • Pins: 2

Pin assignments
Symbol pinNameFootprint padFunction
1terminal-11passive terminal
2terminal-22passive terminal

Interactions

Behaviour that is not a property of this part alone. Each interaction names the records it spans, the conditions it holds under, and how far it has been confirmed. An interaction that spans several parts appears on every one of their pages, under the same identifier, because it is equally a fact about each.

int-c4216-ctrl

  • Records involved: rec-c4216 (this record)

  • Conditions: CTRL divider/RC behavior needs U2 input threshold and source impedance; do not assume result from resistor alone

  • Verdict: NEEDS BENCH

Facts this rests on:

Cross-component rules

Rules that span several parts at once and are published in full on the integration page. Each rule's verdict below is that rule's own — it is a statement about the cross-component question, not about this part — and the exact wording of what the rule refuses to conclude is published with the rule itself.

  • rule-al8860-led-stage — al8860-led-stage — rule verdict: NEEDS BENCH — How the LED driver, its sense resistor, inductor, catch diode and per-branch ballast behave together across the LED forward-voltage, tolerance and temperature envelope.

All cross-component rules

Sources

Every document cited above, with its identification, when it was retrieved, and what kind of authority it carries. Sources that could not be retrieved are listed too, with their unavailability stated, so a gap in the evidence is visible rather than absent.

UNI-ROYAL Thick Film Chip Resistors

Board L generated schematic specification

Legend

What the recorded terms on this page mean, in ordinary words. The exact terms above are the ones that count; these descriptions explain them and never replace them.

Verdict

Recorded termWhat it means
NEEDS BENCHCannot be settled from documents. It needs measurement on real hardware before it can be relied on.
NOT APPLICABLEThe parameter does not apply to this part as it is used here.
PASS - primary-source confirmedConfirmed against the manufacturer's own document for this exact part.

Provenance

Recorded termWhat it means
CALCULATEDDerived arithmetically from other facts listed here. The expression and every input are shown, so the number can be recomputed rather than trusted.
PRIMARY-SPECTaken from the manufacturer's own specification document.
REFERENCE-DESIGNTaken from a vendor reference design or application note rather than the device specification.

Fact class

Recorded termWhat it means
ABSOLUTE_MAXIMUMA never-exceed limit. Reaching it may damage the part; it is not an operating target and there is no margin implied by it.
GUARANTEED_ELECTRICALA parameter the manufacturer guarantees over the stated conditions, usually with minimum, typical and maximum values.
PROJECT_STATEA value this project recorded about how the part is used here — a chosen operating point, a net assignment, or a derived figure. Not a manufacturer specification.
RECOMMENDED_OPERATIONThe range the manufacturer intends the part to be used in. Always narrower than the absolute maximum.
TRANSIENTBehaviour during a short event — startup, a switching edge, a fault or a surge.

Coverage status

Recorded termWhat it means
COVEREDEvery question this domain asks is answered by the facts listed against it.
OPENUnresolved. Open means the question has not been answered, not that the part is unsafe — the reason states what is missing.

Source availability

Recorded termWhat it means
AVAILABLEThe document was retrieved and is on record.

Source authority

Recorded termWhat it means
MANUFACTURER_PRIMARYThe manufacturer's own document for this exact part.
PROJECT_GENERATORA document this project generated, such as a schematic or netlist export.

Identity state

Recorded termWhat it means
UNRESOLVEDThe exact orderable part is not yet confirmed. Substituting a same-name part from another vendor is not permitted on that basis.

Source state

Recorded termWhat it means
SOURCE UNAVAILABLENo document backing this line could be retrieved.

Unit

Recorded termWhat it means
NONEThe value is not a physical quantity, so it carries no unit. Recorded as `NONE`.

Raw agent resource

This page is generated from a stored evidence bundle and does not restate it. The bundle is the source of truth: where the two ever disagree, the bundle is right and this page is stale.

Open the owning bundle component-project-passives